Application
Genine Cummins KTA19-C525 type Diesel Engine for oil field.
Pay attention to.This article will be through how to reduce the failure rate and some typical fault analysis and recommendations.Cummins diesel generator unit fault.
Low oil pressure
In the operation of cummins diesel generator set, low oil pressure will cause poor lubrication of all transmission parts of the unit, and cylinder pulling, cylinder holding and excessive bearing clearance will also occur if the oil circuit is blocked, directly affecting the normal use of cummins diesel generator set.
The low oil pressure of cummins diesel generator is mainly related to the following aspects:
(1) cooling system: oil cooler is blocked;The external space of the radiator core is blocked.
(2) lubrication system: dirty oil filter;Obstructed oil suction pipe;Oil pressure regulator failed.
(3) mechanical adjustment and repair;Improper bearing clearance;The engine needs to be overhauled;Main bearing or connecting rod bearing damaged.
(4) use and maintenance: engine overload;Oil to change on time, to ensure the correct use of oil filter element.Only in accordance with the correct maintenance method to ensure the normal use of the unit..
Product Parameter (Specification)
Start | Electric Start | Stoke | 4 Stoke |
Warranty | 6months | Weight | 1762KG |
Cylinder | Multi-Cylinder | Place Of Origin | Chongqing, China |
Brand Name | CUMMINS | Engine Model | KTA19-C525 |
Production Details